24-Hour Mechanical Time Switch, 208-277 VAC, 60Hz, DPST, Indoor/Outdoor Plastic Enclosure, 1 Hour Interval
Model#T104P
- Proposition 65 warning for California residents
24-Hour Mechanical Time Switch, 208-277 VAC, 60Hz, DPST, Indoor/Outdoor Plastic Enclosure, 1 Hour Interval
Model#T104P
- Proposition 65 warning for California residents
- Direct 24-hour control of most loads
- Up to 12 ON/OFF operations each day with minimum ON/OFF times of one hour
- Manual override
- One ON and one OFF tripper included
- Indoor Lighting Control
- Outdoor Lighting Control
- Timing/Scheduling ON/OFF
Input Voltage Range(s) 208-277 VAC, 60 Hz Maximum ON/OFF Operations 12 Minimum ON/OFF Times 1 hour Operation Mode 24 hour Resistive 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 347 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz Switch Type DPST Application Compatibilities HID, LED CA Prop 65 Message Please see the Warning @ www.P65Warnings.ca.gov California Proposition 65 Lead Color Gray Country of Origin (Intermatic) MEXICO CSA Certification cCSAus Electronic Ballast 16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC Electronic Ballast Load Ratings Ranges 16 A, 120-277 VAC Enclosure Type Indoor/outdoor type 3R plastic Has Manual Override Yes Inductive 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz Inductive Load Ratings Ranges 40 A, 120-277 VAC, 60 Hz Knockout Dimensions Back (1) combination 1/2" - 3/4" Knockout Dimensions Bottom (2) combination 1/2" - 3/4" Maximum Power Consumption (W) 3 W Motor Load Ratings Ranges 2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz Number Of Circuits 1 Number of Trippers Included 1 ON/1 OFF Other Certifications and Compatibilities Green Energy, LED Pilot Duty (NO) 1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz Pilot Duty Load Ratings Ranges 1000 VA, 120-277 VAC, 60 Hz Resistive Load Ratings Ranges 40 A, 120-480 VAC, 60 Hz RoHS Certification X Skipper Wheel Not Included Timing Interval 1 hr Tungsten (NO) 40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz Tungsten Range(s) 40 A, 120-277 VAC, 60 Hz UL Certification cULus Warranty Period 1-Year limited Wire Size Max #8 AWG Wire Size Min #14 AWG Wiring Option Terminals Operating Temperature Max (°C) 54 Operating Temperature Max (°F) 130 Operating Temperature Min (°C) -40 Operating Temperature Min (°F) -40 Product Depth (in) 4 Product Depth (mm) 101.6 Product Height (in) 10 Product Height (mm) 254 Product Width (in) 6.5 Product Width (mm) 165.1 Unit Carton Height (in) 10.06 Unit Carton Length (in) 6.56 Unit Carton Weight (lb) 2.295 Unit Carton Width (in) 4 Units Per Pallet 162